Infusion Pump
Infusion Pombi,
,
FAQ
Mubvunzo: Ndiwe mugadziri wechigadzirwa ichi?
A: Hongu, kubvira 1994.
Mubvunzo: Iwe une CE mucherechedzo wechigadzirwa ichi?
A: Hongu.
Mubvunzo: Iwe uri kambani ISO yakasimbiswa here?
A: Hongu.
Q: Makore mangani waranti yechigadzirwa ichi?
A: Makore maviri waranti.
Mubvunzo: Zuva rekutumira?
A: Kazhinji mukati me1-5 mazuva ekushanda mushure mekubhadhara kwagamuchirwa.
Zvinotsanangurwa
Model | KL-8052N |
Kupomba Mechanism | Curvilinear peristaltic |
IV Set | Inoenderana neIV seti yechero chiyero |
Flow Rate | 0.1-1500 ml/h (mu 0.1 ml/h increments) |
Purge, Bolus | 100-1500 ml/h (mu 1 ml/h increments) Geza kana pombi yamira, bolus panotanga pombi |
Bolus volume | 1-20 ml (mu 1 ml kuwedzera) |
Kururama | ±3% |
*Inbuilt Thermostat | 30-45 ℃, inogona kugadziriswa |
VTBI | 1-9999 ml |
Infusion Mode | ml/h, donho/min, nguva-yakavakirwa |
Nhoroondo ye KVO | 0.1-5 ml/h (mu 0.1 ml/h increments) |
Alarms | Occlusion, air-in-line, gonhi rakavhurika, purogiramu yekupedzisira, bhatiri rakaderera, kuguma kwebhatiri, AC magetsi kudzimwa, mota kusashanda, kusashanda zvakanaka kwehurongwa, kumira |
Zvimwe Zvimiro | Chaiyo-nguva yakapinza vhoriyamu / bolus mwero / bolus vhoriyamu / KVO mwero, otomatiki simba switching, mbeveve kiyi, purge, bolus, system memory, key locker, shandura kuyerera kwehuwandu pasina kumisa pombi |
Occlusion Sensitivity | Pamusoro, pakati, pasi |
Air-in-line Detection | Ultrasonic detector |
WirelessManagement | Optional |
Simba rekupa, AC | 110/230 V (kusarudza), 50-60 Hz, 20 VA |
Bhatiri | 9.6±1.6 V, inochajwa |
Hupenyu hwebhatiri | Maawa mashanu pa30 ml/h |
Kushanda Tembiricha | 10-40 ℃ |
Relative Humidity | 30-75% |
Atmospheric Pressure | 700-1060 hpa |
Size | 174*126*215 mm |
Kurema | 2.5 kg |
Safety Classification | Kirasi Ⅰ, nyora CF |
Features:
1. Yakavakwa-mu thermostat: 30-45 ℃ inogadziriswa.
Iyi nzira inodziya IV tubing kuti iwedzere infusion chokwadi.
Ichi chinhu chakasarudzika kuenzanisa nemamwe Mapombi eInfusion.
2. Inoshanda kune munhu mukuru, Pediatrics uye NICU (Neonatal).
3. Anti-yemahara-kuyerera basa kuita kuti infusion ive yakachengeteka.
4. Chaiyo-nguva kuratidzwa kweiyo infused vhoriyamu / bolus mwero / bolus vhoriyamu / KVO chiyero.
5, Inooneka pa-screen 9 maaramu.
6. Shandura chiyero chekuyerera pasina kumisa pombi.
Muenzaniso KL-8052N
Kupomba Mechanism Curvilinear peristaltic
IV Seti Inopindirana neIV seti yechero chiyero
Flow Rate 0.1-1500 ml/h (mu 0.1 ml/h increments)
Purge, Bolus 100-1500 ml/h (mu 1 ml/h increments)
Geza kana pombi yamira, bolus panotanga pombi
Bolus vhoriyamu 1-20 ml (mu 1 ml increments)
Kururama ±3%
* Inbuilt Thermostat 30-45 ℃, inogona kugadziriswa
VTBI 1-9999 ml
Infusion Mode ml / h, kudonha / min, nguva-yakavakirwa
KVO Rate 0.1-5 ml/h (mu 0.1 ml/h increments)
Alarm Occlusion, air-in-line, gonhi rakavhurika, chirongwa chekupedzisira, bhatiri rakaderera, bhatiri rekupedzisira,
AC magetsi kudzimwa, mota kusashanda, kusashanda zvakanaka kwehurongwa, kumira
Zvimwe Zvimiro Chaiyo-nguva yakapinza vhoriyamu / bolus mwero / bolus vhoriyamu / KVO chiyero,
otomatiki simba switching, mbeveve kiyi, purge, bolus, system memory,
key locker, shandura kuyerera kwehuwandu pasina kumisa pombi
Occlusion Sensitivity Yakakwirira, yepakati, yakaderera
Air-in-line Detection Ultrasonic detector
Wireless Management Optional
Simba rekupa, AC 110/230 V (kusarudza), 50-60 Hz, 20 VA
Bhatiri 9.6±1.6 V, rechargeable
Bhatiri Hupenyu maawa mashanu pa30 ml/h
Kushanda Tembiricha 10-40 ℃
Relative Humidity 30-75%
Atmospheric Pressure 700-1060 hpa
Saizi 174*126*215 mm
Huremu 2.5 kg
Chengetedzo Yekuronga Kirasi Ⅰ, mhando CF
![xqt (8)](https://cdn.globalso.com/kellymedgroup/xqt-8.jpg)
![xqt (7)](https://cdn.globalso.com/kellymedgroup/xqt-7.jpg)
![xqt (5)](https://cdn.globalso.com/kellymedgroup/xqt-5.jpg)
![xqt (6)](https://cdn.globalso.com/kellymedgroup/xqt-6.jpg)
![xqt (4)](https://cdn.globalso.com/kellymedgroup/xqt-4.jpg)
![xqt (3)](https://cdn.globalso.com/kellymedgroup/xqt-3.jpg)
![xqt (1)](https://cdn.globalso.com/kellymedgroup/xqt-1.jpg)
![xqt (2)](https://cdn.globalso.com/kellymedgroup/xqt-2.jpg)